Product Details:
|
Recommended Name: | Vascular Cell Adhesion Protein 1 | Short Names: | V-CAM 1; VCAM-1 |
---|---|---|---|
Alternative Names: | INCAM-100 | Cat. No.: | In-Hu3701 |
CD Antigen Name: | CD106 | Gene Names: | VCAM1 |
Highlight: | CD106 ELISA RUO Test Kit,VCAM1 ELISA RUO Test Kit,VCAM1 CD106 ELISA Test Kit |
Human Vascular Cell Adhesion Molecule 1;VCAM1;CD106;ELISA Kit
Principle
This ELISA kit uses Sandwich-ELISA as the method. The Microelisa stripplate provided in this kit has been pre-coated with an antibody specific to VCAM1/CD106 . Standards or samples are added to the appropriate Microelisa stripplate wells and combined to the specific antibody. Then a Horseradish Peroxidase (HRP)- conjugated antibody specific for VCAM1/CD106 is added to each Microelisa stripplate well and incubated. Free components are washed away. The TMB substrate solution is added to each well. Only those wells that contain VCAM1/CD106 and HRP conjugated VCAM1/CD106 antibody will appear blue in color and then turn yellow after the addition of the stop solution. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm. The OD value is proportional to the concentration of VCAM1/CD106 . You can calculate the concentration of VCAM1/CD106 in the samples by comparing the OD of the samples to the standard curve.
Materials provided with the kit
Materials provided with the kit | 48 determinations | 96 determinations | Storage | |
1 | User manual | 1 | 1 | R.T. |
2 | Closure plate membrane | 2 | 2 | R.T. |
3 | Sealed bags | 1 | 1 | R.T. |
4 | Microelisa stripplate | 1 | 1 | 2-8℃ |
5 | Standard:13.5ng/ml | 0.5ml×1 bottle | 0.5ml×1 bottle | 2-8℃ |
6 | Standard diluent | 1.5ml×1 bottle | 1.5ml×1 bottle | 2-8℃ |
7 | HRP-Conjugate reagent | 3ml×1 bottle | 6ml×1 bottle | 2-8℃ |
8 | Sample diluent | 3ml×1 bottle | 6ml×1 bottle | 2-8℃ |
9 | Chromogen Solution A | 3ml×1 bottle | 6ml×1 bottle | 2-8℃ |
10 | Chromogen Solution B | 3ml×1 bottle | 6ml×1 bottle | 2-8℃ |
11 | Stop Solution | 3ml×1 bottle | 6ml×1 bottle | 2-8℃ |
12 | Wash solution | 20ml (20X)×1bottle | 20ml (30X)×1bottle | 2-8℃ |
Notes:
Store the kit at 4°C upon receipt.The kit should be equilibrated to room temperature before the assay. Remove any unneeded strips from Human VCAM1/CD106Antibody-Coated plate, reseal them in zip-lock foil and keep at 4°C.
Calculation of Results
Known concentrations of Human VCAM1/CD106 Standard and its corresponding reading OD is plotted on the log scale (x-axis) and the log scale (y-axis) respectively. The concentration of Human VCAM1/CD106 in sample is determined by plotting the sample’s O.D. on the Y-axis. The original concentration is calculated by multiplying the dilution factor.
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Human VCAM1/CD106 were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Human VCAM1/CD106 were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Assay range
0.1 ng/ml -10 ng/ml
Sensitivity:
0.01 ng/ml
Contact Person: Mr. Steven
Tel: +8618600464506