logo
  • English
Home ProductsElisa Test Kit

Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality

Certification
China Biovantion Inc. certification
Customer Reviews
Very good. everything was complete. Thanks

—— Maryl Joy Prado-Philippines

Very good and easy communication. The products worked well with both positive controls and test groups. Would order again without hesitation.

—— Olof Olson,United States

I'm Online Chat Now

Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality

Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality
Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality

Large Image :  Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality

Product Details:
Place of Origin: China
Brand Name: Biovantion
Certification: ISO13485
Model Number: TY0027
Payment & Shipping Terms:
Minimum Order Quantity: 10
Price: Negotiable
Packaging Details: CARTON
Delivery Time: 7-15 days
Payment Terms: TT 100% PAYMENT
Supply Ability: 100000

Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality

Description
Country Of Origin: China Format: Kit
Shelf Life: 18 Months Specificity: High
Assay Time: 1.5-3 Hours Test Type: Ferritin Elisa Test Kit
Kit Size: 96 Tests Sample Type: Serum, Plasma,
Highlight:

Enzyme Linked Ferritin Elisa Test Kit

,

High Quality Ferritin Elisa Test Kit

,

Ferritin Elisa Test Kit

Ferritin Elisa Test Kit

 
 

INTENDED USE 

The Ferritin assay is an enzyme-linked immunosorbent assay (ELISA for the in vitro quantitative determination of ferritin in human serum. This assay is useful in diagnosis and screening of anemia. For professional use only.
 

Summary

Ferritin is a macromolecule with a molecular weight of at least 440 kD (depending on the iron content) and consists of a protein shell (apoferritin) of 24 subunits and an iron core containing an average of approx. 2500 Fe3+ ions (in liver and spleen ferritin).1 In humans, it acts as a buffer against iron deficiency and iron overload.2 If the ferritin level is low, there is a risk for lack of iron, which could lead to anemia or iron deficiency without anemia. In the setting of anemia, low serum ferritin is the most specific lab finding for iron-deficiency anemia.3 Low ferritin may also indicate hypothyroidism, vitamin C deficiency or celiac disease. Low serum ferritin levels are seen in some patients with restless legs syndrome, not necessarily related to anemia, but perhaps due to low iron stores short of anemia.4,5 A normal ferritin blood level, referred to as the reference interval is determined by many testing laboratories. The ranges for ferritin can vary between laboratories but typical ranges would be between 30–300 ng/mL (=µg/L) for males, and 30–160 ng/mL (=µg/L) for females. A value less than 50 is considered as iron deficiency. Serum ferritin levels are measured in medical laboratories as part of the iron studies workup for iron-deficiency anemia.6 The ferritin levels measured usually have a direct correlation with the total amount of iron stored in the body.

Test principle

Sandwich principle. Total duration of assay: 80 minutes.
• Sample, Anti-Ferritin coated microwells and enzyme labeled Anti-Ferritin are combined.
• During the incubation, ferritin presents in the sample is allowed to react simultaneously with the two antibodies, resulting in the ferritin molecules being sandwiched between the solid phase and enzyme-linked antibodies.
• After washing, a complex is generated between the solid phase, the Ferritin within the sample and enzyme-linked antibodies by immunological reactions.
• Substrate solution is then added and catalyzed by this complex, resulting in a chromogenic reaction. The resulting chromogenic reaction is measured as absorbance.
• The absorbance is proportional to the amount of ferritin in the sample.

 

Precautions and warnings

 

• For in vitro diagnostic use only. For professional use only.
• All products that contain human serum or plasma have been found to be non
reactive for HBsAg, HCV and HIVI/II. But all products should be reared as
potential biohazards in use and for disposal.
• Mix the sample in the wells thoroughly by shaking and eliminate the bubbles.
• Conduct the assay away from bad ambient conditions. e.g. ambient air
containing high concentration corrosive gas such as sodium hypochlorite acid,
alkaline, acetaldehyde and so on, or containing dust.
• Wash the wells completely. Each well must be fully injected with wash solution.
The strength of injection, however, is not supposed to be too intense to avoid
overflow. In each wash cycle, dry the liquids in each well. Strike the microplate
onto absorbent paper to remove residual water droplets. It is recommended to
wash the microplate with an automated microplate strip washer.
• Failure to remove adhering solution adequately in the aspiration or decantation
wash step(s) may result in poor replication and spurious results.
• Do not use reagents beyond the labeled expiry date.
• Do not mix or use components from kits with different batch codes.
• If more than one plate is used, it is recommended to repeat the calibration
curve.
• It is important that the time of reaction in each well is held constant to achieve
reproducible results.
• Ensure that the bottom of the plate is clean and dry.
• Ensure that no bubbles are present on the surface of the liquid before reading
the plate.
• The substrate and stop solution should be added in the same sequence to
eliminate any time deviation during reaction.

 
 
Technical Parameters:

Product Name:

Ferritin Elisa Test Kit

Manufacturer:

Biovantion

Format:

Kit

Applications:

Diagnosis

Assay Time:

2-3 Hours

Sample Type:

Serum, Plasma

Specificity:

High

Sensitivity:

High

Shelf Life:

18 Months

Kit Size:

96 Tests

 
Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality 0Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality 1Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality 2Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality 3
 
 Ferritin Elisa Test Kit Enzyme-Linked Products Transport Time Short High Quality 4
 
 

Specimen collection and preparation

• Human serum is recommended for this assay.
• Cap and store the samples at 18-25 ℃ for no more than 8 hours. Stable for 7 days at 2-8℃, and 1 month at -20℃. Freeze only once.
• Do not use heat-inactivated samples.
• Sediments and suspended solids in samples may interfere with the test result which should be removed by centrifugation. Ensure that complete clot formation in serum samples has taken place prior to centrifugation.
• Avoid grossly hemolytic, lipemic or turbid samples.

FAQ:

Q: What is the brand name of this test kit?
A: The brand name of this test kit is Biovantion.
Q: Where is this test kit manufactured?
A: This test kit is manufactured in China.
Q: Is this test kit certified?
A: Yes, this test kit is certified with ISO13485.
Q: What is the minimum order quantity for this product?
A: The minimum order quantity for this product is 10.
Q: What is the packaging details for this product?
A: The packaging details for this product is CARTON.
Q: What is the delivery time for this product?
A: The delivery time for this product is 7-15 days.
Q: What are the payment terms for this product?
A: The payment terms for this product is TT 100% PAYMENT.
Q: What is the supply ability for this product?
A: The supply ability for this product is 100000.
Q: Is the price of this product negotiable?
A: Yes, the price of this product is negotiable.

 

Contact Details
Biovantion Inc.

Contact Person: Mr. Steven

Tel: +8618600464506

Send your inquiry directly to us (0 / 3000)